Polartherm Oy
Field Heating Solutions   ► Uusiutuva Energia   ►

Technical data

Technical data
ModelOutput
power
kW
 
Voltage
Phase
V
Power
Req.
kW
Current
Nominal
A
Air
Flow
m3/h
Oil
consum
ption

kg/h
Fan
Press
Pa*
Weight
kg
CI.
number
E30  25 230,1~ 0,4 3 2400 2,1 60 1007551901
E35 40 400,3N~ 1,0-1,4 3,5-4,5 3500 3,8 100 1857551906
E50 52 230,1~ 0,7 5 3000 4,8 60 1707551911
E65 75 400,3N~ 1,3-2,5 4,5-7,0 5000 7,8 100 2957551916
E100 116 400,3N~ 1,9-2,7 5,5-7,5 7700 11,4 100 4007551921
E130 151 400,3N~ 2,7-3,5 7,5-9,0 10300 14,7 100 5807551926
E170 197 400,3N~ 4,4-8,5 9-20 12000 20,0 100 8107551931
E220 255 400,3N~ 8,5 20 15500 25,0 100 8107551936
E260 302 400,3N~ 8,6 20 18000 29,8 100 11007551941
E320 372 400,3N~ 8,5-12,0 20-26 22000 36,0 100 15007551946
E410 476 400,3N~ 8,5-12,0 20-26 27700 45,8 100 15007551951

Heaters are delivered complete including safety equipment, oil burner and controls. 60 Pa / 100 Pa fan pressure is standard. Fan pressure can be increased up to 400 Pa with the exeption of models E 30 and E 50.

Heater selection guide
ModelkWWarehouse 
m3
Workshop
m3
Car repair shop,
Garage  m3
Green-
house  m2
E30 25 1100 900 400 110
E35  40 1600 1300 600 160
E50 52 2300 1850 850 225
E65 75 3000 2400 1100 300
E100 116 4400 3700 1700 400
E130 151 5800 4800 2200 600
E170 197 7400 6300 2900 750
E220 255 9600 8100 3800 1000
E260 302 11500 9500 4400 1200
E320 372 14000 11800 5500 1400
E410 476 17900 15200 7100 1800

The selection guide has been made using an outside / inside temp. difference of 40°C

Interested?